How to set Elevator Stop Running password for Monarch and Step control System

 The STEP set of validity period


After entering the advanced password, a new menu will appear after the new Shida-the validity period of the motherboard.
After confirming, go in and first change the validity period mode to ON, and then set the start time and end time. Before setting the running start, you must first modify the system time to keep the system time and the start time the same. The day you want to stop the elevator.
I want to stop the elevator one day and stop it the other day.
Failure phenomenon after Xinshida's elevator stop: The motherboard does not report a failure, the outgoing call cannot be selected, the door can be selected but not the ladder, and the special can be used to express.
After setting, you need to modify the advanced password.
 
Monarch System sets the stop time
 

The motherboard sets the limited-time running days setting F9-10 running days setting, taking 10 as the base + the number of days to be set, for example, if you want to set 30 days to stop, that is 10 + 30 = 40, so you change F9-10 to 40. OK, the ex-factory is 999, F9-08 is the running hours setting, there is no need to know, as long as you know a method.
 
After Monarch stopped the elevator, the motherboard reported E40 and E34. Password change FP-00 is not 0, the maximum is 65535.